Technical Specifications
FILTER MODULES ARRANGEMENTS
Number of filter modules | 1 | 2 | 3 | 4 | 5 | 6 |
Filtration surface (sq.ft.) | 165 | 330 | 495 | 660 | 825 | 990 |
Dimension (W x D X H) in. | 48” x 48” x 144” | 72” x 48” x 144” | 96” x 48” x 144” | 120” x 48” x 130” | 144” x 48” x 130” | 168” x 48” x 130” |
Module weight (lbs) | 690 | 1 040 | 1 390 | 1 740 | 2 090 | 2 444 |
(When equipped with a hummer blower module, add 18” to width)
STANDARD BLOWER – 3600RPM | HUMMER BLOWER – 1800 RPM | |||||||||
Fan Module | 5HP | 7.5HP | 10HP | 15HP | 20HP | 10HP | 15HP | 20HP | 25 | 30HP |
Capacity (CFM) | 2 500 | 3 500 | 4 600 | 5 000 | 6 000* | 4 600 | 5 000 | 6 000* | 7 500* | 9 000* |
Recommended number of filter modules | 1 to 3 | 2 to 4 | 2 to 5 | 3 to 6 | 4 to 6 | 2 to 5 | 4 to 6 | 4 to 6 | 5 to 7 | 7 to 8 |
Sound pressure (dB) at 10´ (without a silencer) | 82 | 84 | 88 | 92 | 92 | 80 | 81 | 83 | 85 | 87 |
Inlet diameter (in.) | 9 | 10 | 12 | 14 | 16 | 12 | 14 | 16 | 18 | 20 |
Module weight (lbs) | 200 | 240 | 250 | 340 | 360 | 350 | 450 | 560 | 620 | 680 |
* Outdoor installation required.
RECOMMENDED NUMBER OF FILTER MODULES : GUIDELINES
BLOWER | LIGHT USAGE (under 3 hours a day) | MEDIUM USAGE (3 to 6 hours a day) | HEAVY USAGE (more than 6 hours a day) | ||||||
HP | Coarse | Mixed | Fine | Coarse | Mixed | Fine | Coarse | Mixed | Fine |
5HP | 2 | 2 | 2 | 2 | 2 | 2 to 3 | 2 to 3 | 3 | 3 |
7.5HP | 2 | 2 | 2 | 2 | 2 to 3 | 3 | 3 | 3 to 4 | 4 |
10HP | 3 | 3 | 3 | 3 | 3 to 4 | 4 | 4 to 5 | 4 to 5 | 4 to 5 |
15HP | 3 | 3 | 3 | 3 to 4 | 4 | 4 to 5 | 5 | 5 to 6 | 6 |
20HP | 4 | 4 | 4 | 4 | 4 to 5 | 4 to 5 | 4 to 5 | 5 to 6 | 5 to 6 |